The BK-GC901 gas chromatograph features full electronic flow control (EPC) and complete computer-based instrument control; it can also be equipped with a high-precision automatic liquid sampler. It is widely used across various sectors—including the petroleum and chemical industries, environmental protection, food safety, disease control, education, and scientific research—enabling the analysis of macro-, micro-, and trace-level organic and inorganic substances, as well as gases.
Technical Specifications
Model: BK-GC901
Oven
Temperature range: RT+5 to 450°C
Temperature accuracy: ≤±0.01°C
Temperature programming: 16-stage
Maximum heating rate: 40°C/min
Time range: 0–999.9 min
Detector
Flame Ionization Detector (FID):
Detection limit: ≤5×10⁻¹² g/s (using a 100 ng/µL solution of n-hexadecane in isooctane)
Temperature: 450°C
Compatible with both packed and capillary columns. Baseline drift: ≤2×10⁻¹³ A/30 min
Baseline noise: 3×10⁻¹⁴ A
Linear range: ≥10⁷
Thermal Conductivity Detector (TCD):
Sensitivity: >5000 mV·mL/mg (50 mg/mL solution of toluene in benzene)
Temperature: 400°C
Baseline drift: ≤0.1 mV/30 min
Baseline noise: 0.03 mV
Linear range: ≥10⁵ (±10%)
Electron Capture Detector (ECD):
Detection limit: ≤1×10⁻¹⁴ g/mL (Sample: n-hexadecane/δ-666)
Linear range: ≥10⁴
Flame Photometric Detector (FPD):
Detection limit: ≤5×10⁻¹² g/s (S from a 10 ng/µL solution of methyl parathion in ethanol)
Detection limit: ≤4×10⁻¹² g/s (P from a 10 ng/µL solution of methyl parathion in ethanol)
Linear range (S): ≥10³
Linear range (P): ≥10⁴
Temperature: 350°C
Nitrogen-Phosphorus Detector (NPD):
Detection limit: ≤1×10⁻¹² g/s (azobenzene)
Detection limit: ≤1×10⁻¹² g/s (sulfur-phosphorus compound)
Linear range: ≥10³
Injection method: Capillary column with Split/splitless sampling (with septum purge function), packed column sampling, valve-based sampling, automatic gas/liquid sampling system, etc.
Inlets: 1–4, supporting up to 3 capillary column inlets
Injection type: Packed column injection, capillary column injection (flow rate setting range: 0–1000 mL/min)
Control precision: Pressure: 0.01 kPa; Flow rate: 0.01 mL/min
Maximum split ratio: 1:999
Pressure sensor: Accuracy: <2% of full scale; Reproducibility: <±0.05 kPa; Range: 0–0.6 MPa
Flow sensors: Accuracy: <5% of full scale; Repeatability: 0.5 kPa (full scale); Output signal deviation (accuracy): ±5%
Sampling valve: Can be equipped with multiple imported automatic control valves, capable of sequential automated operation.
Power supply: AC 220V ±10%, 50/60 Hz
Standard accessories: Flame Ionization Detector (FID), chromatography workstation software, capillary sampler.
Optional accessories: Sample introduction system, TCD, ECD, FPD, and NPD detectors, chromatographic columns.
Package dimensions (W×D×H): 750 × 710 × 720 mm
Gross weight: 70 kg