Magnetic Field Generator
Model 1008 is available with the following loop antennas:
1008-02 – square antenna, 1 x 1 m
1008-03 – square antenna, 1.5 x 1.5 m
1008-04 – square antenna, 2 x 2 m
1008-05 – rectangular antenna, 2 x 1.6 m
1008-06 – circular antenna, 1 m
1008-07 – circular antenna, 40 cm
The 1008 system is an integrated solution for magnetic field immunity testing in accordance with IEC 1000-4-8 and EN 61000-4-8 standards. The system consists of a programmable current generator (1008-01) and a loop antenna, which is available in various sizes to accommodate the dimensions of the device under test.
The generator is equipped with an output current sensor to monitor the stability of the magnetic field produced by the loop antenna, compensating for variations caused by cable heating, connection points, or fluctuations in mains voltage.
An audible alarm sounds during testing to alert the user.