UZ RU EN
About Products Services Discounts Reviews News Our Partners Contacts
Пн–Пт: 9:00–18:00 г. Ташкент, ул. Фурката, 175 info@ntechnology.uz +998 90 189-52-23
← Back to catalog
Analyzer 3000CS
Mettler-Toledo

Analyzer 3000CS

Price on request

The 3000CS is a reliable, online analyzer for the direct measurement of chloride and sulfate in pure water and power plant cycle chemistry. This instrument detects these highly corrosive ions to prevent damage to critical power plant components.

Chloride Measurement Range — 0–300 ppb
Chloride Limit of Detection — 0.5 ppb
Chloride Measurement Accuracy — ±5% of reading or ±0.5 ppb, whichever is greater
Sulfate Measurement Range — 0–300 ppb
Sulfate Limit of Detection — 1 ppb
Sulfate Measurement Accuracy — ±10% of reading or ±1 ppb, whichever is greater
Measurement Cycle Time — 45 min typical; programmable 15–60 min
Sample Flow Rate — 25–50 mL/min
Sample Temperature — 10–45 °C (50–113 °F)
Sample Pressure — 0.3–7 bar (5–100 psig)
Grab Sample Measurement — Included; 100 mL capacity
Power Supply — 100–240 VAC, 50–60 Hz, 100 W typical
Dimensions (HxWxD) — 927 x 508 x 305 mm (36.5 x 20.9 x 12 in)
Weight — 44 kg (97 lb)
Ambient Operating Temperature — 10–35 °C (50–95 °F)
Humidity — 10–70% non-condensing
Ratings/Approvals — CE; cULus
Process Connection — Sample inlet 1/4 in or 6 mm OD stainless compression fitting; drain hose 19 x 25.4 mm, 2 m included
Operator Interface — Color touchscreen; simultaneous ion concentrations and analyzer status
Analog Output — 22 mA alarm; 500 ohm maximum load
Analog Output Scaling — Linear; bi-linear; logarithmic (1–4 decades); autoranging
Measurement Parameter — Chloride and sulfate
Relay Contacts — Mechanical 250 VAC, 3 A (relay 1 NC, relays 2–4 NO); four SPDT reed 250 VAC/DC, 0.5 A
Analog Output Accuracy — ±0.05 mA
Model Family — 3000CS
Enclosure Type — Full
Built-in Sequencer — No

Request a quote