Temperature / Working-temperature range — 5 °C above ambient temperature up to +50 °C
Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors)
Temperature / Setting temperature range — +18 to +50 °C
Temperature / Setting accuracy temperature — 0.1 °C
Temperature / Temperature sensor — 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
Temperature / Temperature variation in chamber — at + 37 °C +/- 0.3 K
Temperature / Temperature fluctuations with time — at 37 °C +/- 0.1 K
Humidity / Humidity control (standard) — Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93 % rh +/- 2.5 %
Humidity / Setting accuracy humidity — 0.5 % rh
Humidity / Setting range active humidity control (with option K7) — 40 to 97 % rh and rh-Off
Control of standard components / CO 2 control — Digital electronic CO 2 control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation
Control of standard components / Adjustment range CO 2 — 0 to 20 % CO 2
Control of standard components / Setting accuracy CO2 — 0,1%
Control of standard components / Variation in time CO 2 — +/- 0.2 % CO 2
Control of standard components / Adjustment range O 2 — 1 to 20 % O 2
Control of standard components / Setting accuracy O 2 — 0.1 % O 2
Control technology / ControlCOCKPIT — TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
Control technology / Language setting — German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Control technology / Function SetpointWAIT — the process time does not start until the set temperature is reached
Control technology / Adjustable parameters — temperature (Celsius or Fahrenheit), CO 2 , programme time, time zones, summertime/wintertime
Communication / Interface — Ethernet LAN,
USB
Communication / Documentation — programme stored in case of power failure
Communication / Programming — AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port
Safety / AutoSAFETY — additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature
Safety / Autodiagnostic system — integral fault diagnostics for temperature and CO 2
Safety / Alarm — visual and acoustic
Heating concept / 6 sides — large-area multi-function heating system on four sides with additional door and back heating to avoid condensation
Standard equipment / Works calibration certificate — Works calibration certificate at +37 °C, 5 % CO 2 and 90 % rh (requires option K7); standard equipment for units with active humidity control
Standard equipment / Works calibration certificate — Works calibration certificate at +37 °C, 5 % CO 2 , 90 % rh and 10 % O 2 (requires option K7 and option T6); standard equipment for units with O 2 control
Standard equipment / Works calibration certificate — incl. works calibration certificate (measuring point chamber centre) at +37°C, 5 % CO 2 for standard units
Standard equipment / Door — fully insulated stainless steel door with 2-point locking (compression door lock)
Standard equipment / Door — inner glass door with opening (8 mm Ø) to take gas sample
Standard equipment / Standard equipment — CO 2 connection set: hose with coupling and clamp
Standard equipment / Standard accessories — Membrane filter (in order to remove impurities and pollutants, all incoming gases pass through a membrane filter before they reach the chamber)
Standard equipment / Internals — 1 perforated stainless steel shelf/shelves
Standard equipment / Internals — 1 stainless steel water dish
Stainless steel interior / Dimensions — w (A) x h (B) x d (C) : 400 x 425 x 330 mm (d less 35 mm for fan)
Stainless steel interior / Interior — material 1.4301 (ASTM 304), corrosion resistant
Stainless steel interior / Volume — 56 l
Stainless steel interior / Max. number of internals — 5
Stainless steel interior / Max. loading of chamber — 75 kg
Stainless steel interior / Max. loading per internal — 15 kg
Textured stainless steel casing / Dimensions — w (D) x h (E) x d (F) : 559 x 795 x 521 mm (d +56mm door handle)
Textured stainless steel casing / Housing — rear zinc-plated steel
Electrical data / Voltage
Electrical load — 230 V, 50/60 Hz
approx. 1100 W
Electrical data / Voltage
Electrical load — 115 V, 50/60 Hz
approx. 1100 W
Ambient conditions / Set Up — The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Ambient conditions / Ambient temperature — 10 °C to 35 °C
Ambient conditions / Humidity rh — max. 70 %, non-condensing
Ambient conditions / Altitude of installation — max. 2,000 m above sea level
Ambient conditions / Overvoltage category — II
Ambient conditions / Pollution degree — 2
Packing/shipping data / Transport information — The appliances must be transported upright
Packing/shipping data / Customs tariff number — 8419 8998
Packing/shipping data / Country of origin — Federal Republic of Germany
Packing/shipping data / WEEE-Reg.-No. — DE 66812464
Packing/shipping data / Dimensions approx incl. carton — w x h x d: 730 x 950 x 640 mm
Packing/shipping data / Net weight — approx. 55 kg
Packing/shipping data / Gross weight carton — approx. 74 kg